Skip to content

M18

Tipping bucket at the top: fills up and dumps its contents in one big splash

Height
2493 mm
Overall dimensions
2560 × 1080 mm
Wet zone
Ø ≈ 2 m
M18, product render

Wet zone

The bucket at the top slowly fills and then tips over in one big splash. The splash zone under the bucket has a diameter of about 2 metres; the drawing also shows the footprint of the frame.

  • Splash zone under the tipping bucket, Ø ≈ 2 m
  • Overall dimensions of the object

Indicative, based on AVASTO test values. Wind, water pressure and the choice of spray nozzle determine the actual reach; we agree this with you for each project.

Plan view of the wet zone, 1 m grid2.56 m1.08 m1 mr ≈ 1 m
Plan view, 1 × 1 m grid

Gallery

Impressions based on the 3D model; details of the element may differ.

Specifications

* Indicative: confirmed for each project.

Colour

Two RAL colours: the feet with base plates, and the tubular frame. Choose from the nine colour lines or your own RAL colours.

M18

Dimensions

Total height
2493 mm
Overall dimensions
2560 × 1080 mm
Tube / base plate
Ø168.3 mm / 2× Ø300 × 10 mm
Weight
approx. 117 kg excl. bucket (indicative)

Water and operation

Spray nozzle
fill line to the tipping bucket, flow rate to be determined; chosen per project (indicative)
Wet zone
splash zone under the bucket, approx. Ø 2 m (indicative)

Material and colour

Construction
Stainless steel 316, powder-coated; welded to EN 1090-2, EXC2
Finish
Powder coating in two RAL colours: the feet (supports + base plates) and the tube; colour change at the seam between base and tube
Colour
RAL Classic of your choice, separately for tube and base. Shown: RAL 3004 / RAL 9010

Installation

Anchoring
Cast-in anchor, 4× M16, to be cast in with the concrete (indicative)
Foundation
Concrete slab or pad footing as specified by the structural engineer; anchor level and flush with the finished floor
Fixing
Base plate with 4 nuts, covered with caps in the base colour
Fixings in 1.4529
on request (indicative)

Safety and maintenance

Daily maintenance
Visual check; indoors, rinse with mains water
Weekly maintenance
Clean the spray nozzle, remove limescale and dirt
Six-monthly maintenance
Indoors: NEN 9200 inspection of stainless steel and fixings
Winter maintenance
Outdoors: drain the supply and blow it dry (indicative)
Standard (indoors)
NEN 9200:2025; the element is in zone A (splash zone). Stainless steel 316 is permitted provided it is inspectable and traceable, checked weekly, inspected every six months and regularly rinsed with mains water

Elements with wet zone

For these elements we show the full specifications and the wet zone.

Contact

Feel free to contact us for more information. We are of course also happy to talk to you by phone.

Design, installation and maintenance by AVASTO Recreation Technology

AVASTO Recreation TechnologyPopulierenweg 41, 3421 TX Oudewater

+31 (0)348 - 560297 recreatietechniek@avasto.nl